de acuerdo con el disco duro SMART no está roto, pero tengo errores en dmesg


12

A veces tengo problemas extraños para arrancar mi computadora (que ejecuta Debian). Así que emití el comando "dmesg". En su salida vi muchos errores. Sin embargo, cuando ejecuto la prueba SMART extendida en discos duros (usando el comando "smartctl -t long / dev / sda"), el resultado es que mis discos no están rotos.

¿Cuál puede ser la razón de esos errores?

Aquí están los errores:

   (...)
      [  505.918537] ata3.00: exception Emask 0x50 SAct 0x400 SErr 0x280900 action 0x6 frozen
      [  505.918549] ata3.00: irq_stat 0x08000000, interface fatal error
      [  505.918558] ata3: SError: { UnrecovData HostInt 10B8B BadCRC }
      [  505.918566] ata3.00: failed command: READ FPDMA QUEUED
      [  505.918579] ata3.00: cmd 60/40:50:20:5b:60/00:00:0b:00:00/40 tag 10 ncq 32768 in
               res 40/00:54:20:5b:60/00:00:0b:00:00/40 Emask 0x50 (ATA bus error)
      [  505.918586] ata3.00: status: { DRDY }
      [  505.918595] ata3: hard resetting link
      [  506.410055] ata3: SATA link up 3.0 Gbps (SStatus 123 SControl 300)
      [  506.422648] ata3.00: configured for UDMA/133
      [  506.422679] ata3: EH complete
      [ 1633.123880] md: bind<sdb3>
      [ 1633.187966] RAID1 conf printout:
      [ 1633.187977]  --- wd:1 rd:2
      [ 1633.187984]  disk 0, wo:0, o:1, dev:sda3
      [ 1633.187989]  disk 1, wo:1, o:1, dev:sdb3
      [ 1633.188866] md: recovery of RAID array md0
      [ 1633.188871] md: minimum _guaranteed_  speed: 1000 KB/sec/disk.
      [ 1633.188875] md: using maximum available idle IO bandwidth (but not more than 200000 KB/sec) for recovery.
      [ 1633.188890] md: using 128k window, over a total of 1943618560k.
      [ 1634.167341] ata3.00: exception Emask 0x50 SAct 0x7f80 SErr 0x280900 action 0x6 frozen
      [ 1634.167353] ata3.00: irq_stat 0x08000000, interface fatal error
      [ 1634.167361] ata3: SError: { UnrecovData HostInt 10B8B BadCRC }
      [ 1634.167369] ata3.00: failed command: READ FPDMA QUEUED
      [ 1634.167382] ata3.00: cmd 60/00:38:00:00:6f/02:00:01:00:00/40 tag 7 ncq 262144 in
               res 40/00:6c:00:0c:6f/00:00:01:00:00/40 Emask 0x50 (ATA bus error)
      [ 1634.167389] ata3.00: status: { DRDY }
      [ 1634.167395] ata3.00: failed command: READ FPDMA QUEUED
      [ 1634.167407] ata3.00: cmd 60/00:40:00:02:6f/02:00:01:00:00/40 tag 8 ncq 262144 in
               res 40/00:6c:00:0c:6f/00:00:01:00:00/40 Emask 0x50 (ATA bus error)
      [ 1634.167413] ata3.00: status: { DRDY }
      [ 1634.167418] ata3.00: failed command: READ FPDMA QUEUED
      [ 1634.167429] ata3.00: cmd 60/00:48:00:04:6f/02:00:01:00:00/40 tag 9 ncq 262144 in
               res 40/00:6c:00:0c:6f/00:00:01:00:00/40 Emask 0x50 (ATA bus error)
      [ 1634.167435] ata3.00: status: { DRDY }
      [ 1634.167439] ata3.00: failed command: READ FPDMA QUEUED
      [ 1634.167451] ata3.00: cmd 60/00:50:00:06:6f/02:00:01:00:00/40 tag 10 ncq 262144 in
               res 40/00:6c:00:0c:6f/00:00:01:00:00/40 Emask 0x50 (ATA bus error)
      [ 1634.167457] ata3.00: status: { DRDY }
      [ 1634.167462] ata3.00: failed command: READ FPDMA QUEUED
      [ 1634.167473] ata3.00: cmd 60/00:58:00:08:6f/02:00:01:00:00/40 tag 11 ncq 262144 in
               res 40/00:6c:00:0c:6f/00:00:01:00:00/40 Emask 0x50 (ATA bus error)
      [ 1634.167479] ata3.00: status: { DRDY }
      [ 1634.167484] ata3.00: failed command: READ FPDMA QUEUED
      [ 1634.167495] ata3.00: cmd 60/00:60:00:0a:6f/02:00:01:00:00/40 tag 12 ncq 262144 in
               res 40/00:6c:00:0c:6f/00:00:01:00:00/40 Emask 0x50 (ATA bus error)
      [ 1634.167500] ata3.00: status: { DRDY }
      [ 1634.167505] ata3.00: failed command: READ FPDMA QUEUED
      [ 1634.167516] ata3.00: cmd 60/80:68:00:0c:6f/00:00:01:00:00/40 tag 13 ncq 65536 in
               res 40/00:6c:00:0c:6f/00:00:01:00:00/40 Emask 0x50 (ATA bus error)
      [ 1634.167522] ata3.00: status: { DRDY }
      [ 1634.167527] ata3.00: failed command: READ FPDMA QUEUED
      [ 1634.167538] ata3.00: cmd 60/00:70:80:0c:6f/02:00:01:00:00/40 tag 14 ncq 262144 in
               res 40/00:6c:00:0c:6f/00:00:01:00:00/40 Emask 0x50 (ATA bus error)
      [ 1634.167544] ata3.00: status: { DRDY }
      [ 1634.167553] ata3: hard resetting link
      [ 1634.658816] ata3: SATA link up 3.0 Gbps (SStatus 123 SControl 300)
      [ 1634.672645] ata3.00: configured for UDMA/133
      [ 1634.672696] ata3: EH complete
      [ 1637.687898] ata3.00: exception Emask 0x50 SAct 0x3ff000 SErr 0x280900 action 0x6 frozen
      [ 1637.687910] ata3.00: irq_stat 0x08000000, interface fatal error
      [ 1637.687918] ata3: SError: { UnrecovData HostInt 10B8B BadCRC }
      [ 1637.687926] ata3.00: failed command: READ FPDMA QUEUED
      [ 1637.687940] ata3.00: cmd 60/00:60:80:a7:af/02:00:02:00:00/40 tag 12 ncq 262144 in
               res 40/00:ac:00:b4:af/00:00:02:00:00/40 Emask 0x50 (ATA bus error)
      [ 1637.687947] ata3.00: status: { DRDY }
      [ 1637.687953] ata3.00: failed command: READ FPDMA QUEUED
      [ 1637.687965] ata3.00: cmd 60/00:68:80:a9:af/02:00:02:00:00/40 tag 13 ncq 262144 in
               res 40/00:ac:00:b4:af/00:00:02:00:00/40 Emask 0x50 (ATA bus error)
      [ 1637.687971] ata3.00: status: { DRDY }
      [ 1637.687976] ata3.00: failed command: READ FPDMA QUEUED
      [ 1637.687987] ata3.00: cmd 60/80:70:80:ab:af/01:00:02:00:00/40 tag 14 ncq 196608 in
               res 40/00:ac:00:b4:af/00:00:02:00:00/40 Emask 0x50 (ATA bus error)
      [ 1637.687993] ata3.00: status: { DRDY }
      [ 1637.687998] ata3.00: failed command: READ FPDMA QUEUED
      [ 1637.688009] ata3.00: cmd 60/00:78:00:ad:af/02:00:02:00:00/40 tag 15 ncq 262144 in
               res 40/00:ac:00:b4:af/00:00:02:00:00/40 Emask 0x50 (ATA bus error)
      [ 1637.688015] ata3.00: status: { DRDY }
      [ 1637.688020] ata3.00: failed command: READ FPDMA QUEUED
      [ 1637.688031] ata3.00: cmd 60/80:80:00:af:af/00:00:02:00:00/40 tag 16 ncq 65536 in
               res 40/00:ac:00:b4:af/00:00:02:00:00/40 Emask 0x50 (ATA bus error)
      [ 1637.688037] ata3.00: status: { DRDY }
      [ 1637.688042] ata3.00: failed command: READ FPDMA QUEUED
      [ 1637.688053] ata3.00: cmd 60/00:88:80:af:af/01:00:02:00:00/40 tag 17 ncq 131072 in
               res 40/00:ac:00:b4:af/00:00:02:00:00/40 Emask 0x50 (ATA bus error)
      [ 1637.688059] ata3.00: status: { DRDY }
      [ 1637.688064] ata3.00: failed command: READ FPDMA QUEUED
      [ 1637.688075] ata3.00: cmd 60/80:90:80:b0:af/00:00:02:00:00/40 tag 18 ncq 65536 in
               res 40/00:ac:00:b4:af/00:00:02:00:00/40 Emask 0x50 (ATA bus error)
      [ 1637.688081] ata3.00: status: { DRDY }
      [ 1637.688085] ata3.00: failed command: READ FPDMA QUEUED
      [ 1637.688096] ata3.00: cmd 60/00:98:00:b1:af/02:00:02:00:00/40 tag 19 ncq 262144 in
               res 40/00:ac:00:b4:af/00:00:02:00:00/40 Emask 0x50 (ATA bus error)
      [ 1637.688102] ata3.00: status: { DRDY }
      [ 1637.688107] ata3.00: failed command: READ FPDMA QUEUED
      [ 1637.688118] ata3.00: cmd 60/00:a0:00:b3:af/01:00:02:00:00/40 tag 20 ncq 131072 in
               res 40/00:ac:00:b4:af/00:00:02:00:00/40 Emask 0x50 (ATA bus error)
      [ 1637.688124] ata3.00: status: { DRDY }
      [ 1637.688129] ata3.00: failed command: READ FPDMA QUEUED
      [ 1637.688140] ata3.00: cmd 60/00:a8:00:b4:af/01:00:02:00:00/40 tag 21 ncq 131072 in
               res 40/00:ac:00:b4:af/00:00:02:00:00/40 Emask 0x50 (ATA bus error)
      [ 1637.688146] ata3.00: status: { DRDY }
      [ 1637.688154] ata3: hard resetting link
      [ 1638.179398] ata3: SATA link up 3.0 Gbps (SStatus 123 SControl 300)
      [ 1638.192977] ata3.00: configured for UDMA/133
      [ 1638.193029] ata3: EH complete
      [ 1640.259492] md: export_rdev(sdb1)
      [ 1640.326109] md: bind<sdb1>
      [ 1640.346712] RAID1 conf printout:
      [ 1640.346724]  --- wd:1 rd:2
      [ 1640.346731]  disk 0, wo:0, o:1, dev:sda1
      [ 1640.346736]  disk 1, wo:1, o:1, dev:sdb1
      [ 1640.346893] md: delaying recovery of md1 until md0 has finished (they share one or more physical units)
      [ 1657.987964] ata3.00: exception Emask 0x50 SAct 0x40000 SErr 0x280900 action 0x6 frozen
      [ 1657.987975] ata3.00: irq_stat 0x08000000, interface fatal error
      [ 1657.987984] ata3: SError: { UnrecovData HostInt 10B8B BadCRC }
      [ 1657.987992] ata3.00: failed command: READ FPDMA QUEUED
      [ 1657.988006] ata3.00: cmd 60/00:90:00:30:2e/03:00:09:00:00/40 tag 18 ncq 393216 in
               res 40/00:94:00:30:2e/00:00:09:00:00/40 Emask 0x50 (ATA bus error)
      [ 1657.988013] ata3.00: status: { DRDY }
      [ 1657.988022] ata3: hard resetting link
      [ 1658.479548] ata3: SATA link up 3.0 Gbps (SStatus 123 SControl 300)
      [ 1658.493107] ata3.00: configured for UDMA/133
      [ 1658.493147] ata3: EH complete
      [ 1670.547791] ata3: limiting SATA link speed to 1.5 Gbps
      [ 1670.547805] ata3.00: exception Emask 0x50 SAct 0x7f SErr 0x280900 action 0x6 frozen
      [ 1670.547812] ata3.00: irq_stat 0x08000000, interface fatal error
      [ 1670.547820] ata3: SError: { UnrecovData HostInt 10B8B BadCRC }
      [ 1670.547826] ata3.00: failed command: READ FPDMA QUEUED
      [ 1670.547839] ata3.00: cmd 60/80:00:00:1f:2e/01:00:0c:00:00/40 tag 0 ncq 196608 in
               res 40/00:2c:00:26:2e/00:00:0c:00:00/40 Emask 0x50 (ATA bus error)
      [ 1670.547846] ata3.00: status: { DRDY }
      [ 1670.547852] ata3.00: failed command: READ FPDMA QUEUED
      [ 1670.547863] ata3.00: cmd 60/80:08:80:20:2e/00:00:0c:00:00/40 tag 1 ncq 65536 in
               res 40/00:2c:00:26:2e/00:00:0c:00:00/40 Emask 0x50 (ATA bus error)
      [ 1670.547869] ata3.00: status: { DRDY }
      [ 1670.547875] ata3.00: failed command: READ FPDMA QUEUED
      [ 1670.547886] ata3.00: cmd 60/00:10:00:21:2e/02:00:0c:00:00/40 tag 2 ncq 262144 in
               res 40/00:2c:00:26:2e/00:00:0c:00:00/40 Emask 0x50 (ATA bus error)
      [ 1670.547892] ata3.00: status: { DRDY }
      [ 1670.547896] ata3.00: failed command: READ FPDMA QUEUED
      [ 1670.547907] ata3.00: cmd 60/00:18:00:23:2e/02:00:0c:00:00/40 tag 3 ncq 262144 in
               res 40/00:2c:00:26:2e/00:00:0c:00:00/40 Emask 0x50 (ATA bus error)
      [ 1670.547913] ata3.00: status: { DRDY }
      [ 1670.547918] ata3.00: failed command: READ FPDMA QUEUED
      [ 1670.547929] ata3.00: cmd 60/00:20:00:25:2e/01:00:0c:00:00/40 tag 4 ncq 131072 in
               res 40/00:2c:00:26:2e/00:00:0c:00:00/40 Emask 0x50 (ATA bus error)
      [ 1670.547935] ata3.00: status: { DRDY }
      [ 1670.547940] ata3.00: failed command: READ FPDMA QUEUED
      [ 1670.547951] ata3.00: cmd 60/00:28:00:26:2e/02:00:0c:00:00/40 tag 5 ncq 262144 in
               res 40/00:2c:00:26:2e/00:00:0c:00:00/40 Emask 0x50 (ATA bus error)
      [ 1670.547957] ata3.00: status: { DRDY }
      [ 1670.547961] ata3.00: failed command: READ FPDMA QUEUED
      [ 1670.547972] ata3.00: cmd 60/00:30:00:28:2e/02:00:0c:00:00/40 tag 6 ncq 262144 in
               res 40/00:2c:00:26:2e/00:00:0c:00:00/40 Emask 0x50 (ATA bus error)
      [ 1670.547978] ata3.00: status: { DRDY }
      [ 1670.547987] ata3: hard resetting link
      [ 1671.039264] ata3: SATA link up 1.5 Gbps (SStatus 113 SControl 310)
      [ 1671.053386] ata3.00: configured for UDMA/133
      [ 1671.053444] ata3: EH complete
      [ 2422.512002] md: md0: recovery done.
      [ 2422.547344] md: recovery of RAID array md1
      [ 2422.547355] md: minimum _guaranteed_  speed: 1000 KB/sec/disk.
      [ 2422.547360] md: using maximum available idle IO bandwidth (but not more than 200000 KB/sec) for recovery.
      [ 2422.547378] md: using 128k window, over a total of 4877312k.
      [ 2422.668465] RAID1 conf printout:
      [ 2422.668474]  --- wd:2 rd:2
      [ 2422.668480]  disk 0, wo:0, o:1, dev:sda3
      [ 2422.668486]  disk 1, wo:0, o:1, dev:sdb3
      [ 2469.990451] md: md1: recovery done.
      [ 2470.049986] RAID1 conf printout:
      [ 2470.049997]  --- wd:2 rd:2
      [ 2470.050003]  disk 0, wo:0, o:1, dev:sda1
      [ 2470.050009]  disk 1, wo:0, o:1, dev:sdb1
      [ 3304.445149] PM: Hibernation mode set to 'platform'
      [ 3304.782375] PM: Syncing filesystems ... done.
      [ 3307.028591] Freezing user space processes ... (elapsed 0.001 seconds) done.
      (...)

1
Esto podría estar relacionado con un cable SATA o de alimentación defectuoso, o tal vez una fuente de alimentación defectuosa.
Thomas

1
También lo he visto con controladores malos que se congelan y necesitan reiniciarse.
Stephen Harris

1
Agregué una respuesta a esta pregunta que incluía una salida dmesg similar pero no idéntica, por ejemplo (sd 1: 0: 0: 0: rechazar E / S al dispositivo fuera de línea y advertencia EXT4-fs) Creo que esto habría ayudado a las personas a buscar el problema en Google . La respuesta se eliminó aunque no coincidía con ninguno de los motivos establecidos en unix.stackexchange.com/help/deleted-answers . Tuve el problema en un SSD montado en / home. Intenté desconectar y volver a conectar el cable de alimentación y SATA pero el error persistió. Afortunadamente tenía un cable SATA de repuesto. Después de reemplazar el cable SATA, no tuve errores y el problema no se volvió a solucionar.
htaccess

Respuestas:


21

Primero, tenga en cuenta que SMART dice que su unidad está en buen estado no necesariamente significa que la unidad esté en buen estado. Los informes SMART son una ayuda , no una verdad absoluta.

Si todo lo que le interesa es qué hacer, en lugar de por qué, no dude en desplazarse hasta los últimos párrafos; sin embargo, el texto provisional le dirá por qué creo que lo que propongo es el curso de acción correcto y cómo derivarlo de lo que publicó.

Dicho esto, veamos qué nos dice uno de esos errores.

[ 1670.547805] ata3.00: exception Emask 0x50 SAct 0x7f SErr 0x280900 action 0x6 frozen
[ 1670.547812] ata3.00: irq_stat 0x08000000, interface fatal error
[ 1670.547820] ata3: SError: { UnrecovData HostInt 10B8B BadCRC }
[ 1670.547826] ata3.00: failed command: READ FPDMA QUEUED
[ 1670.547839] ata3.00: cmd 60/80:00:00:1f:2e/01:00:0c:00:00/40 tag 0 ncq 196608 in
           res 40/00:2c:00:26:2e/00:00:0c:00:00/40 Emask 0x50 (ATA bus error)
[ 1670.547846] ata3.00: status: { DRDY }
[ 1670.547852] ata3.00: failed command: READ FPDMA QUEUED

(Espero tener las partes que deberían ir juntas, pero estabas obteniendo un paquete de esas, así que debería estar bien de cualquier manera).

El Linux ata Wiki tiene una página que explica cómo leer estos errores . Particularmente,

  • Un statusvalor de DRDYsignifica "Dispositivo listo. Normalmente 1, cuando todo está bien". Ver un valor de estado de DRDYes perfectamente normal y esperado.
  • SError tiene múltiples valores de componentes, de los cuales está viendo (en este fragmento particular):
    • UnrecovData "Se produjo un error de integridad de datos, la interfaz no se recuperó"
    • HostInt "Error interno del adaptador de bus host"
    • 10B8B "Se produjo un error de decodificación de 10b a 8b"
    • BadCRC "Se produjo un error CRC de la capa de enlace"

La codificación 10b8b, que codifica 8 bits como 10 bits para ayudar con la sincronización de la señal y la detección de errores, se utiliza en el cableado físico, no necesariamente en el propio disco. Lo más probable es que la unidad utilice otras formas de codificación FEC o ECC, y un error allí normalmente se mostrará como alguna forma de error de E / S, probablemente con un errorvalor de UNC("error no corregible, a menudo debido a sectores defectuosos en el disco") , probablemente con "error de medios" ("el software detectó un error de medios") entre paréntesis al final de la reslínea. Esto último no es lo que está viendo, por lo que si bien no podemos descartarlo por completo, parece poco probable.

La "capa de enlace" es los cables físicos y trazas de placa de circuito entre la propia controladora de la unidad, y el chip de interfaz de unidad de disco (probablemente parte de la southbridge en la placa base del ordenador, pero podría estar situada en una offboard HBA).

Un adaptador de bus host, también conocido como HBA, es el circuito que se conecta al equipo de almacenamiento. También conocido coloquialmente como "controlador de disco", un término que es un poco inapropiado con los sistemas modernos. La parte más visible del HBA generalmente son los puertos de conexión, con mayor frecuencia en la actualidad, ya sea SATA o algún factor de forma SAS.

Las banderas UnrecovDatay HostIntbásicamente nos dicen que "algo salió terriblemente mal y no hubo forma de recuperarse o no se hizo ningún intento de recuperación". Lo contrario probablemente sería RecovData, lo que indica que se produjo un "error de integridad de datos, pero la interfaz se recuperó". (Como comentario aparte, probablemente lo hubiera usado en HBAIntlugar de hacerlo HostInt, ya que el "host" se refiere al HBA, no a todo el sistema).

La combinación de 10B8By BadCRC, que apuntan a la capa de enlace físico, me hace sospechar un problema de cableado.

Esta sospecha también está respaldada por el hecho de que las autocomprobaciones SMART, que son completamente internas de la unidad, excepto por el informe de estado, no encuentran errores que el fabricante considere que son lo suficientemente graves como para justificar el informe en los resultados. Si la unidad tenía problemas para almacenar o leer datos, la larga autoevaluación SMART en particular debería haberlo informado.

TL; DR:

Lo primero que haría es simplemente desconectar y volver a enchufar el cable SATA en ambos extremos; puede estar ligeramente flojo, lo que hace que pierda contacto eléctrico de manera intermitente. Vea si eso resuelve el problema. Incluso podría valer la pena hacer esto con todos los cables SATA de su computadora, no solo con el disco afectado. Si está utilizando un HBA externo, también quitaría y volvería a colocar esa tarjeta, principalmente porque es algo fácil de probar mientras ya está jugando con el cableado.

De lo contrario, intente tirar y reemplazar el cable SATA, preferiblemente con un cable de alta calidad. Un cable de alta calidad será un poco más caro, pero creo que generalmente vale la pena el pequeño gasto adicional si ayuda a evitar dolores de cabeza como este. ¡A nadie le gusta ver sus errores de almacenamiento arrojando!


2
Desconecté y volví a enchufar el cable SATA y resolvió el problema. ¡Gracias!
user983447

@ user983447 ¡Me alegra haber podido ayudar!
un CVn

0

En mi caso, noté que había conectado dos discos en dos controladores de disco diferentes: el primero era PCI-Express y el segundo PCI normal. Me deshice del error de BadCRC cuando conecté los dos discos RAID en el mismo controlador.


1
Entonces, cuando ese controlador muere, ¿se lleva ambos discos?
roaima

Sí, pero es mucho más probable que el disco muera que el controlador. Además, sería una mejor idea NO utilizar el controlador PCI, sino un controlador PCI-Express de alta velocidad.
PHZ.fi-Pharazon
Al usar nuestro sitio, usted reconoce que ha leído y comprende nuestra Política de Cookies y Política de Privacidad.
Licensed under cc by-sa 3.0 with attribution required.