Tengo una máquina con Windows 7 de 64 bits que se congela aproximadamente una vez al mes. Los últimos cinco minivolcados indican "Causado por dirección" ntoskrnl.exe + 4b314c, y estoy tratando de averiguar quién posee (o está activando llamadas fallidas) del código en esa dirección.
Aquí está la !analyze -v
salida del mini-dump más reciente:
Microsoft (R) Windows Debugger Version 6.3.9600.17029 AMD64
Copyright (c) Microsoft Corporation. All rights reserved.
Loading Dump File [C:\Windows\Minidump\102116-50450-01.dmp]
Mini Kernel Dump File: Only registers and stack trace are available
************* Symbol Path validation summary **************
Response Time (ms) Location
Deferred SRV*C:\SymCache*http://msdl.microsoft.com/download/symbols
Symbol search path is: SRV*C:\SymCache*http://msdl.microsoft.com/download/symbols
Executable search path is:
Windows 7 Kernel Version 7601 (Service Pack 1) MP (12 procs) Free x64
Product: WinNt, suite: TerminalServer SingleUserTS
Built by: 7601.19160.amd64fre.win7sp1_gdr.160211-0600
Machine Name:
Kernel base = 0xfffff800`04201000 PsLoadedModuleList = 0xfffff800`04448730
Debug session time: Fri Oct 21 16:47:24.260 2016 (UTC - 7:00)
System Uptime: 0 days 0:00:25.275
Loading Kernel Symbols
.
Press ctrl-c (cdb, kd, ntsd) or ctrl-break (windbg) to abort symbol loads that take too long.
Run !sym noisy before .reload to track down problems loading symbols.
..............................................................
..........
Loading User Symbols
Mini Kernel Dump does not contain unloaded driver list
*******************************************************************************
* *
* Bugcheck Analysis *
* *
*******************************************************************************
Use !analyze -v to get detailed debugging information.
BugCheck 124, {0, fffffa802d3f77c8, 0, 0}
Probably caused by : GenuineIntel
Followup: MachineOwner
---------
7: kd> !analyze -v
*******************************************************************************
* *
* Bugcheck Analysis *
* *
*******************************************************************************
WHEA_UNCORRECTABLE_ERROR (124)
A fatal hardware error has occurred. Parameter 1 identifies the type of error
source that reported the error. Parameter 2 holds the address of the
WHEA_ERROR_RECORD structure that describes the error conditon.
Arguments:
Arg1: 0000000000000000, Machine Check Exception
Arg2: fffffa802d3f77c8, Address of the WHEA_ERROR_RECORD structure.
Arg3: 0000000000000000, High order 32-bits of the MCi_STATUS value.
Arg4: 0000000000000000, Low order 32-bits of the MCi_STATUS value.
Debugging Details:
------------------
BUGCHECK_STR: 0x124_GenuineIntel
CUSTOMER_CRASH_COUNT: 1
DEFAULT_BUCKET_ID: WIN7_DRIVER_FAULT
PROCESS_NAME: System
CURRENT_IRQL: 0
ANALYSIS_VERSION: 6.3.9600.17029 (debuggers(dbg).140219-1702) amd64fre
STACK_TEXT:
fffff880`03d1d6f0 fffff800`044c5cb9 : fffffa80`2d3f77a0 fffffa80`24f7eb50 00000000`00000029 00000000`00000000 : nt!WheapCreateLiveTriageDump+0x6c
fffff880`03d1dc10 fffff800`043a4c07 : fffffa80`2d3f77a0 fffff800`0441f2d8 fffffa80`24f7eb50 00000000`00000000 : nt!WheapCreateTriageDumpFromPreviousSession+0x49
fffff880`03d1dc40 fffff800`0430bc55 : fffff800`04481ba0 00000000`00000001 fffffa80`2d456090 fffffa80`24f7eb50 : nt!WheapProcessWorkQueueItem+0x57
fffff880`03d1dc80 fffff800`0427e065 : fffff880`01776e00 fffff800`0430bc30 fffffa80`24f7eb00 00000000`00000000 : nt!WheapWorkQueueWorkerRoutine+0x25
fffff880`03d1dcb0 fffff800`0450fc6a : 00000000`00000000 fffffa80`24f7eb50 00000000`00000080 fffffa80`24eda870 : nt!ExpWorkerThread+0x111
fffff880`03d1dd40 fffff800`04266086 : fffff880`03b31180 fffffa80`24f7eb50 fffff880`03b3c1c0 00000000`00000000 : nt!PspSystemThreadStartup+0x5a
fffff880`03d1dd80 00000000`00000000 : fffff880`03d1e000 fffff880`03d18000 fffff880`03d1d9e0 00000000`00000000 : nt!KxStartSystemThread+0x16
STACK_COMMAND: kb
FOLLOWUP_NAME: MachineOwner
MODULE_NAME: GenuineIntel
IMAGE_NAME: GenuineIntel
DEBUG_FLR_IMAGE_TIMESTAMP: 0
IMAGE_VERSION:
FAILURE_BUCKET_ID: X64_0x124_GenuineIntel_PROCESSOR_MAE_PRV
BUCKET_ID: X64_0x124_GenuineIntel_PROCESSOR_MAE_PRV
ANALYSIS_SOURCE: KM
FAILURE_ID_HASH_STRING: km:x64_0x124_genuineintel_processor_mae_prv
FAILURE_ID_HASH: {435e2195-e498-1e77-0526-f8d7450275e5}
Followup: MachineOwner
Y aquí está la salida de !errrec fffffa802d3f77c8
7: kd> !errrec fffffa802d3f77c8
===============================================================================
Common Platform Error Record @ fffffa802d3f77c8
-------------------------------------------------------------------------------
Record Id : 01d22bf56b81ac86
Severity : Fatal (1)
Length : 864
Creator : Microsoft
Notify Type : Machine Check Exception
Timestamp : 10/21/2016 23:47:24 (UTC)
Flags : 0x00000002 PreviousError
===============================================================================
Section 0 : Processor Generic
-------------------------------------------------------------------------------
Descriptor @ fffffa802d3f7848
Section @ fffffa802d3f7920
Offset : 344
Length : 192
Flags : 0x00000001 Primary
Severity : Fatal
Proc. Type : x86/x64
Instr. Set : x64
Error Type : Micro-Architectural Error
Flags : 0x00
CPU Version : 0x00000000000206c0
Processor ID : 0x0000000000000000
===============================================================================
Section 1 : x86/x64 Processor Specific
-------------------------------------------------------------------------------
Descriptor @ fffffa802d3f7890
Section @ fffffa802d3f79e0
Offset : 536
Length : 64
Flags : 0x00000000
Severity : Fatal
Local APIC Id : 0x0000000000000000
CPU Id : c0 06 02 00 00 08 20 00 - ff e3 9e 02 ff fb eb bf
00 00 00 00 00 00 00 00 - 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 - 00 00 00 00 00 00 00 00
===============================================================================
Section 2 : x86/x64 MCA
-------------------------------------------------------------------------------
Descriptor @ fffffa802d3f78d8
Section @ fffffa802d3f7a20
Offset : 600
Length : 264
Flags : 0x00000000
Severity : Fatal
Error : Unknown (Proc 0 Bank 2)
Status : 0xb200000000010005
Esta es una máquina de caja blanca construida hace varios años (con piezas actualizadas con el tiempo para mantenerse al día). Periódicamente me aseguro de que todavía pase todas las pruebas de estrés que puedo lanzar (Prime95, Memtest86, etc.). Intenté algunas pruebas breves sin fallas, y voy a volver a ejecutar ciclos completos durante la noche.
Pensé que las congelaciones comenzaron originalmente después de que instalé varias piezas de software (posiblemente incluyendo controladores) hace un año o dos, pero no tuve tiempo para investigar o solucionar problemas en ese momento. No puedo recordar qué software habría sido o exactamente cuándo (y para ser honesto, eso podría no estar relacionado o un conjunto diferente de BSOD ya resuelto). Pasé un tiempo atrás y eliminé software / controladores, particularmente cualquier cosa que pudiera parecer sospechosa o aparecida en otros BSOD más antiguos (por ejemplo, cosas como cbfs5.sys).
He aplicado las actualizaciones de BIOS más recientes y los controladores más recientes que funcionan correctamente para mí. (Parte del hardware es antiguo y, en casos excepcionales, descubrí que los controladores más nuevos causan otros problemas). La mayoría de las actualizaciones de Windows están instaladas (puede haber algunas en los últimos meses que aún no se han aplicado; dado que es una estación de trabajo bastante crítica, adopto un enfoque muy controlado para las actualizaciones, creando una imagen de copia de seguridad completa de antemano y haciendo un conjunto de pruebas de regresión después de cada ciclo de actualización. Como resultado, la actualización es lenta, pero en general esta máquina es más estable y predecible que otras que mantengo que están configuradas para actualizarse automáticamente. Esa es una razón por la que estoy posponiendo Win 10 por ahora )
Todas las temperaturas parecen razonables.
Mi sistema está configurado para escribir volcados de memoria del kernel, pero por razones desconocidas para mí, no se escribe uno cuando ocurre este problema (ocurrió hoy antes, pero mi MEMORY.DMP en esa ruta tiene una fecha modificada de hace casi un mes).
La placa base es un Asus P6T6 WS Revolution (chipset X58) y la CPU es un Intel Xeon E5645 Hex Core de 2.4GHz. Tengo 48 GB de RAM ECC instalados.
No tengo mucha experiencia analizando volcados de memoria, y agradecería cualquier ayuda / sugerencia.