En el transcurso de una semana, para una unidad Seagate de 3 TB (ST3000DM001-1CH166), smartd informó un número cada vez mayor de sectores fuera de línea no corregibles y actualmente ilegibles (pendientes), luego un número decreciente, hasta que finalmente el recuento fue 0 y la condición de error Reiniciar. De los registros (que muestran solo los cambios):
Jul 6 18:04:57 x smartd[462]: Device: /dev/sdb [SAT], 8 Currently unreadable (pending) sectors
Jul 6 18:04:58 x smartd[462]: Device: /dev/sdb [SAT], 8 Offline uncorrectable sectors
[...]
Jul 7 16:34:58 x smartd[462]: Device: /dev/sdb [SAT], 16 Currently unreadable (pending) sectors (changed +8)
Jul 7 16:34:58 x smartd[462]: Device: /dev/sdb [SAT], 16 Offline uncorrectable sectors (changed +8)
[...]
Jul 11 14:04:57 x smartd[462]: Device: /dev/sdb [SAT], 24 Currently unreadable (pending) sectors (changed +8)
Jul 11 14:04:57 x smartd[462]: Device: /dev/sdb [SAT], 24 Offline uncorrectable sectors (changed +8)
Jul 11 14:34:57 x smartd[462]: Device: /dev/sdb [SAT], 32 Currently unreadable (pending) sectors (changed +8)
Jul 11 14:34:58 x smartd[462]: Device: /dev/sdb [SAT], 32 Offline uncorrectable sectors (changed +8)
[...]
Jul 13 09:04:57 x smartd[462]: Device: /dev/sdb [SAT], 24 Currently unreadable (pending) sectors (changed -8)
Jul 13 09:04:57 x smartd[462]: Device: /dev/sdb [SAT], 24 Offline uncorrectable sectors (changed -8)
Jul 13 09:34:58 x smartd[462]: Device: /dev/sdb [SAT], 16 Currently unreadable (pending) sectors (changed -8)
Jul 13 09:34:58 x smartd[462]: Device: /dev/sdb [SAT], 16 Offline uncorrectable sectors (changed -8)
Jul 13 10:04:57 x smartd[462]: Device: /dev/sdb [SAT], 16 Currently unreadable (pending) sectors
Jul 13 10:04:57 x smartd[462]: Device: /dev/sdb [SAT], 16 Offline uncorrectable sectors
Jul 13 10:34:57 x smartd[462]: Device: /dev/sdb [SAT], No more Currently unreadable (pending) sectors, warning condition reset after 1 email
Jul 13 10:34:57 x smartd[462]: Device: /dev/sdb [SAT], No more Offline uncorrectable sectors, warning condition reset after 1 email
Además, el recuento de sectores reasignados también es 0, por lo que los sectores no parecen haber sido reasignados. Aquí está la smartctl -a
salida completa (actual) para la unidad:
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.14.4-100.fc19.x86_64] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.14 (AF)
Device Model: ST3000DM001-1CH166
Serial Number: W1F30FK2
LU WWN Device Id: 5 000c50 06129a9a8
Firmware Version: CC27
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Wed Jul 16 11:23:08 2014 EDT
==> WARNING: A firmware update for this drive may be available,
see the following Seagate web pages:
http://knowledge.seagate.com/articles/en_US/FAQ/207931en
http://knowledge.seagate.com/articles/en_US/FAQ/223651en
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 584) seconds.
Offline data collection
capabilities: (0x73) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 347) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x3085) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 115 099 006 Pre-fail Always - 91131424
3 Spin_Up_Time 0x0003 094 094 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 12
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 078 060 030 Pre-fail Always - 59138260
9 Power_On_Hours 0x0032 094 094 000 Old_age Always - 5888
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 12
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 0 0
189 High_Fly_Writes 0x003a 097 097 000 Old_age Always - 3
190 Airflow_Temperature_Cel 0x0022 053 049 045 Old_age Always - 47 (Min/Max 23/51)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 10
193 Load_Cycle_Count 0x0032 096 096 000 Old_age Always - 8086
194 Temperature_Celsius 0x0022 047 051 000 Old_age Always - 47 (0 22 0 0 0)
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 5703h+56m+25.808s
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 11838196191
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 211237637103
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
He descargado pero todavía no ejecuto Seatools en la unidad, pero el estado SMART actual de la unidad básicamente parece estar bien. ¿Qué podría causar tal comportamiento?
ACTUALIZACIÓN: Para futuros lectores, el disco estuvo realmente bien durante un par de meses más, momento en el que más sectores se vuelven incorregibles / fuera de línea, y el número de sectores reasignados comenzó a aumentar más allá de 0, y la autocomprobación larga SMART comenzó a fallar con una lectura error. Así que estos mensajes parecían ser una advertencia temprana útil.